DTE-3F3 distribution board for photovoltaic installation

The DTE-3F3 switchboard is used to reduce the three-phase network voltage generated by a photovoltaic installation by connecting additional electricity receivers to individual phases.

SKU DTE-3F3 Category

116.26 (143.00 z VAT)

In stock

Description

The DTE-3F3 switchboard is used to reduce the three-phase network voltage generated by a photovoltaic installation by connecting additional electricity receivers to individual phases.
Additional loads are connected separately to each phase when the voltage on that phase exceeds the voltage set by the user. Programmable settings:
Upper shutdown limit (1V step) ~210-270
Voltage hysteresis (1V step) ~1-10
(voltage drop from upper limit)
Switch-on response time (step 1 sec) 0-10 sec Rated current – 10A Maximum current – 16A Rated power – 2.3kW Maximum power – 3.5kW Operating voltage – 50-400V AC

Upper limit adjustment range – 210-270V AC Voltage hysteresis – 1-10V Upper limit switch-off time – 0.02 sec

Additional information

Dimensions 23 mm

Specifications

Nominal current – 10A
Maximum current – 16A
Nominal power – 2.3kW
Maximum power – 3.5kW
Operating voltage – 50-400V AC
Upper limit adjustment range – 210-270V AC
Voltage hysteresis – 1-10V
Upper limit switch-off time – 0.02 sec